FlexFilter

Modular designed dust collector

Dust collector with 2-stage filtration. Central inlet with velocity reducer. Fully automatic filter cleaning. Can easily be equipped with a great variety of filter materials, bins, emptying systems, etc. Standard equipped with circular bags of polypropylene. PTFE or antistatic filters on request.

Technical data
, , ,
Capacity (max airflow m3/h) Single 1600 Single RF 1800 Twin 3200 Twin RF 3600
Certifications CE
Compressed air consumption 0,6 Nl/cleaning pulse (intermitent 700 NL/min)
Compressed air requirement 6 - 10 bar (dry)
Dustbin volume (l) 70 (per filter)
Filter Area (m2) 12 (per filter)
Filter cleaning method Reverse air pulse
Installation ,
Material Sheet metal
Ambient air -20 to +40 Deg. C. (with anti freeze in compressed air) Process air max +60 Deg. C.
FlexFilter single

ArtNo: 40118600

Filter material
PTFE category M according to DIN EN 60335-2-69
Number of filter elements
1
Weight (kg)
195
FlexFilter single RF

ArtNo: 40118601

Filter material
Polypropylene (Standard)
Number of filter elements
1
Clarification for technical data
With reverse flow filter cleaning
Weight (kg)
215
FlexFilter single aut empt w fra

ArtNo: 40118604

Filter material
Polypropylene (Standard)
Number of filter elements
1
Weight (kg)
302
FlexFilter twin

ArtNo: 40118605

Filter material
Polypropylene (Standard)
Number of filter elements
2
Weight (kg)
367
FlexFilter twin RF

ArtNo: 40118606

Filter material
Polypropylene (Standard)
Number of filter elements
2
Clarification for technical data
With reverse flow filter cleaning
Weight (kg)
375
FlexFilter single Cyclone

ArtNo: 40118618

Filter material
Polypropylene (Standard)
Weight (kg)
188

Accessories for this product 11

Control filter
ArtNo: 40114060

Control filter

Firealarm filters compl.
ArtNo: 40116540

Firealarm filters compl. The Fire alarm is activated when the temperature exceeds +140 Deg. C. It can stop the vacuum unit if wired to the Nederman High Vacuum Starter. Can be used as a trigger warnings such as external fire alarm, If installed whitin EX zone, intrinsic safe circuit must be used. Voltage: 24V AC/DC.

Connection pipe
ArtNo: 40117630

Connection pipe

TVS200 DA
ArtNo: 40117640

TVS200 DA

TVS200 NC
ArtNo: 40117650

TVS200 NC

Housing module A standard
ArtNo: 40118020

Housing module A standard

Top module A
ArtNo: 40118510

Top module A

Filter module cyclone insert
ArtNo: 40119751

Filter module cyclone insert

Diff.pressure switch 3-15 kPa NC
ArtNo: 40375273

Diff.pressure switch 3-15 kPa NC

Control Filter cpl
ArtNo: 40376897

Control Filter cpl

Control Filter cpl HEPA
ArtNo: 40376898

Control Filter cpl HEPA