FMCZ cartridge filter

FMCZ  cartridge filter
FMCZ  cartridge filter
FMC200-2_bin.tif
FMC200-2_flange.tif
FMC200-4_bin.tif
FMC200-4_flange.tif
FMC200-6_bin.tif
FMC200-6_flange.tif
FMC200-8_bin.tif
FMC200-8_flange.tif
FMCZ200 ex membranes.tif

Compact cartridge filter for solving combustible dust problems within a wide range of industries.

  • Quick release waste bin

  • Cartridges are available in a wide variety of materials to suit most applications, whatever the type and quantity of dust

  • Their modular compact design means they can be installed close to the source of dust, thus reducing energy consumption.

  • Their modular compact design means they can be installed close to the source of dust, thus reducing energy consumption.

  • Intelligent ECO-efficient filter controller minimize maintenance and energy costs.

Product details
Models
Accessories
Technical data
Documents (0)
Videos (0)
Spare parts

The FMC cartridge filter series offers many operational benefits thanks to its compact design and patented UniClean® system. The special design of UniClean® cartridges guarantees consistent and effective cleaning. The filter cartridges are available in two different lengths (type L or A).
The FMC filters are designed for air volumes between 1 200-21 000 m3/h containing different types of dust. The FMC filters can be fitted with different types of filter cartridges, positioned vertically to prevent dust building up on the filter material.

The filter is designed for an outdoor location and is as standard designed for a top mounted fan.
Independently tested with ATEX compliant features for for combustible dust.

Standard cartridges in polyester CA100: 10 g/m3 max. fine or coarse dust.
Cartridge in cellulose CA175: 1 g/m3 max. cold fumes

Inlet and outlet dimensions 160, 250, 315, 400, 500 or 560 mm.
Air inlet section adapted for a deflector/wear plate.
Primary separation chamber option with perforated screen.
Measurement of differential pressure and control of the cleaning system: DFC-8M, energy supply 230 V – 50 Hz, 110V - 60 Hz.

Loading...

ApplicationFumes;Dust
Operating Temperature-20 to 70 Deg. C.
Filter cleaning methodPulse jet
MaterialHousing in galvanised sheet steel (2mm)
CertificationsCE;EX
Compressed air requirement6 bar
Suitable for combustible dusttrue
Dustbin volume (l)50 or 100 or without
Working pressure (kPa)-6,0 to 1,5. Operation of the filter with overpressure only allowed if it is a silo top version.
Capacity (max airflow m3/h)21000
Compressed air consumption45 Nl per cleaning pulse