OSF 1000-2 HE

FibreDrain® oil smoke collector for continuous operation.
Two (2) filter stages. An optional pre-filter is available.
Gauges for reading of pressure drop over each filter stage
Extension legs
Two (2) Ø200mm inlet locations, one blanked using clamp ring connection.
Push button start/stop with integral overload protection.
The Nederman OSF (Oil Smoke Filter) is designed to handle large amounts of oil smoke during continuous operation. They are engineered for high efficiency filtration coupled with lower maintenance costs.
The OSF 1000-2 HE has an internal, radial fan wheel and two-stage filtration, as standard. The first stage consists of a filter cassette with Nederman’s FibreDrain® technology. The second stage is a class H13 HEPA filter with a 99.95% efficiency for MPPS, per EN1822. All tower-style OMF units are designed to accept an optional pre-filter. Nederman offers a wide selection of filters to fit a range of different applications.
Loading...
| Capacity (max airflow cfm) | 589 |
| Certifications | CE |
| Filter cleaning method | Self-Draining |
| Filter efficiency (%) | 99.95 |
| Installation | Indoor |
| Material | Sheet metal, painted inside and outside. |
| Noise level (dB(A)) | 68 dB(A) @ 5' from service side |
| Operating Temperature | 104° F, internal fan. |
| Protection class | IP55 |
| Standard | 2009/125/EC |
| Volume (for shipping) (ft³) | 76.28 |
| Working pressure (in. wg) | 10.0” (External) |
| Suitable for combustible dust | false |