NCF Fan incl. sound enclosure
A complete fan imbedded in a sound isolation box
Nederman NCF fan sound enclosures are complete and consist of a NCF fan, flexible connections between fan and inside box, vibration absorbers and cable gland for electrical connection. The fan motor has integrated cooling. The NCF fan is available in a wide range of airflow, from 3000 up to 18 000m³/h (1765 to 10 600 CFM)All sound enclosures are designed for both indoor and outdoor use, and are possible to lift from underneath with a fork lift.Parts are made of 1,2 mm galvanised steel and isolated with dedicated, sound absorbing, 40 mm polyurethane foam. Three sizes of sound enclosures cover all NCF fans. Perfect to install together with one or several Nederman extraction arms like: Original arm, Telescopic arm, NEX MD arm etc or for vehicle exhaust extraction, and can be controlled with a fan starter or a fan inverter. Note! The fan must not be used in an environment with danger of explosion or for transport of inflammable or explosive gases.
-
High sound isolation
-
Available for all NCF fans
-
Delivered with removable doors and two handles
| Cerifikat |
CE |
| Beskyttelsesklasse |
IP 55 |
| Installation |
Indendørs, Udendørs |
| Materiale |
Galvanised steel |
| Omgivelsernes temperatur |
-20 ºC to +40 °C |
| Driftstemperatur |
-20 °C to +80 °C |
| Frekvens (Hz) |
50 |
| Faser |
3 |
Soundbox 4.01 with NCF 20/18 56-R 224 230/400V 2,2kW 50Hz
Lydniveau (dB(A))
46,5 dB(A) at 2000 m³/h
Afklaring af tekniske data
Lp dB(A) i 1 m (rør på ind-og afgang i lydboks)
Soundbox 4.01 with NCF 30/23 56-R 250 400/690V 4,0kW 50Hz
Lydniveau (dB(A))
50 dB(A) ved 3000 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.01 with NCF 40/30 56-R 280 400/690V 5,5kW 50Hz
Lydniveau (dB(A))
53,8 dB(A) ved 4000 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.01 with NCF 40/41 40-R 224 400/690V 7,5kW 50Hz
Lydniveau (dB(A))
58,3 dB(A) at 4000 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.02 with NCF 75/30 63-R 355 400/690V 7,5kW 50Hz
Lydniveau (dB(A))
54,6 dB(A) at 7500 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.02 with NCF 95/26 71-R 400 400/690V 11,0kW 50Hz
Lydniveau (dB(A))
55,6 dB(A) ved 9500 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.02 with NCF 110/38 63-R 400 400/690V 15,0kW 50Hz
Lydniveau (dB(A))
58,1 dB(A) ved 11000 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
Soundbox 4.02 with NCF 140/40 67-R 450 400/690V 18,5kW 50Hz
Lydniveau (dB(A))
59,5 dB(A) ved 14000 m³/h
Afklaring af tekniske data
Lp dB(A) in 1 m (ducted inlet & outlet in soundbox)
ArtNo: 14502437
FMS 4-6.3 ventilator starter manuel
|
ArtNo: 14502537
FMS 6.3-10 ventilator starter manuel
|
ArtNo: 14502637
FMS 10-16 ventilator starter manuel
|
ArtNo: 14521937
Ventilator inverter 4
|
ArtNo: 14522037
Ventilator inverter 5,5
|
ArtNo: 14522137
Frekvensomformer 7,5
|
ArtNo: 14522237
Frekvensomformer 11
|
ArtNo: 14522637
Frekvensomformer 15
|
ArtNo: 14525137
Frekvensomformer 18,5
|
ArtNo: 14528037
Frekvensomformer 2,2
|
ArtNo: 73009962
Fan starter DOL for motor 5,5kW / 400VAC | 5,5kW - DOL | ELC-FanStart-D100-055
|
ArtNo: 73009963
Fan starter Y/D for motor 11kW / 400VAC | 11kW - Y/D | ELC-FanStart-Y100-110
|
ArtNo: 73009964
Fan starter Y/D for motor 18,5kW / 400VAC | 18,5kW - Y/D | ELC-FanStart-Y100-185
|